<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Sanyo PLC-XW55 &#8211; DLP Lamp Guide &#8211; LCD and DLP Repair Tips &#8211; Fix Your DLP &#8211; FixYourDLP.com</title>
	<atom:link href="http://www.fixyourdlp.com/tag/sanyo-plc-xw55/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.fixyourdlp.com</link>
	<description>Your Community For DLP Projector Repair Tips!</description>
	<lastBuildDate>Wed, 25 Jan 2017 04:44:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>
	<item>
		<title>Installing a new lamp for Sanyo PLC-XW50/PLC-XW55 projectors</title>
		<link>http://www.fixyourdlp.com/2012/01/18/installing-a-new-lamp-for-sanyo-plc-xw50plc-xw55-projectors/</link>
					<comments>http://www.fixyourdlp.com/2012/01/18/installing-a-new-lamp-for-sanyo-plc-xw50plc-xw55-projectors/#respond</comments>
		
		<dc:creator><![CDATA[Shelagh McNally]]></dc:creator>
		<pubDate>Thu, 19 Jan 2012 04:50:02 +0000</pubDate>
				<category><![CDATA[FixYourDLP]]></category>
		<category><![CDATA[Projector Lamp Replacement Guides]]></category>
		<category><![CDATA[authentic projector lamps]]></category>
		<category><![CDATA[genuine projector lamps]]></category>
		<category><![CDATA[lamp replace]]></category>
		<category><![CDATA[POA-LMP107]]></category>
		<category><![CDATA[replace projector lamp for Sanyo projectors]]></category>
		<category><![CDATA[replacement projector lamps]]></category>
		<category><![CDATA[Sanyo PLC-XW50]]></category>
		<category><![CDATA[Sanyo PLC-XW55]]></category>
		<category><![CDATA[Sanyo POA-LMP107 (service parts no 610 330 4564]]></category>
		<category><![CDATA[Sanyo POA-LMP107 (sSanyo POA-LMP107 (610 330 4564)]]></category>
		<guid isPermaLink="false">http://www.fixyourdlp.com/?p=2293</guid>

					<description><![CDATA[<p>When it’s time to change your projector lamp on either your SanyoPLC-XW50 or Sanyo PLC-XW55 projector, you&#8217;ll notice a yellow light blinking on the Top Control panel. This is the lamp replacement indicator letting you know it&#8217;s to replace your Sanyo POA-LMP107 &#8230;</p>
<p class="read-more"> <a class="" href="http://www.fixyourdlp.com/2012/01/18/installing-a-new-lamp-for-sanyo-plc-xw50plc-xw55-projectors/"> <span class="screen-reader-text">Installing a new lamp for Sanyo PLC-XW50/PLC-XW55 projectors</span> Read More &#187;</a></p>
<p>The post <a rel="nofollow" href="http://www.fixyourdlp.com/2012/01/18/installing-a-new-lamp-for-sanyo-plc-xw50plc-xw55-projectors/">Installing a new lamp for Sanyo PLC-XW50/PLC-XW55 projectors</a> appeared first on <a rel="nofollow" href="http://www.fixyourdlp.com">DLP Lamp Guide - LCD and DLP Repair Tips - Fix Your DLP - FixYourDLP.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="attachment_2294" style="width: 310px" class="wp-caption alignleft"><a href="http://www.fixyourdlp.com/uploads/SANYO-PLC-XW55.jpg"><img decoding="async" aria-describedby="caption-attachment-2294" class="size-medium wp-image-2294 " src="http://www.fixyourdlp.com/uploads/SANYO-PLC-XW55-300x123.jpg" alt="Sanyo PLC-XW55 projector, Sanyo POA-LMP107 (service parts no 610 330 4564) " width="300" height="123" srcset="http://www.fixyourdlp.com/uploads/SANYO-PLC-XW55-300x123.jpg 300w, http://www.fixyourdlp.com/uploads/SANYO-PLC-XW55.jpg 800w" sizes="(max-width: 300px) 100vw, 300px" /></a><p id="caption-attachment-2294" class="wp-caption-text">Sanyo PLC-XW55 projector</p></div>
<p>When it’s time to change your projector lamp on either your SanyoPLC-XW50 or Sanyo PLC-XW55 projector, you&#8217;ll notice a yellow light blinking on the Top Control panel. This is the lamp replacement indicator letting you know it&#8217;s to replace your <a href="http://www.discount-merchant.com/sanyo-poa-lmp107-replacement-projector-lamp-with-housing-by-philips.html#.WIgtBZI_Uwg" target="_blank">Sanyo POA-LMP107 (service parts no 610 330 4564)</a> projector lamp.</p>
<p>It&#8217;s important the buy only a <a href="http://www.fixyourdlp.com/2011/12/02/7-tips-for-spotting-counterfeits/" target="_blank">genuine </a><a href="http://www.fixyourdlp.com/2011/12/02/7-tips-for-spotting-counterfeits/" target="_blank">POA-LMP107</a> to replace the old lamp. The price of counterfeit knock-off lamps may be tempting but can cost you more money in the long run. Counterfeit lamps are not manufactured according to Sanyo&#8217;s specifications and can <a href="http://www.fixyourdlp.com/2011/11/11/go-with-original-replacement-projection-lamps/" target="_blank">damage the sensitive (and expensive) mechanisms</a> in your Sanyo PLC-XW50/PLC-XW55.</p>
<div id="attachment_2295" style="width: 310px" class="wp-caption alignright"><a href="http://www.fixyourdlp.com/uploads/XW50.jpg"><img decoding="async" aria-describedby="caption-attachment-2295" class="size-full wp-image-2295 " src="http://www.fixyourdlp.com/uploads/XW50.jpg" alt="Sanyo PLC- XW50 projector, Sanyo POA-LMP107 (service parts no 610 330 4564)" width="300" height="121" /></a><p id="caption-attachment-2295" class="wp-caption-text">Sanyo PLC- XW50 projector</p></div>
<h3></h3>
<h3><strong>STEP-BY-STEP INSTRUCTIONS FOR </strong><strong></strong><strong> LAMP REPLACEMENT<br />
</strong></h3>
<p><strong></strong><strong>Before installation of the </strong><strong><a href="http://www.discount-merchant.com/sanyo-poa-lmp107-replacement-projector-lamp-with-housing-by-philips.html#.WIgtBZI_Uwg" target="_blank">Sanyo POA-LMP107 (service parts no 610 330 4564)</a></strong> lamp: Turn off the projector and unplug the AC cord. Allow the Sanyo PLC-XW50/PLC-XW55 projector to cool for one hour – it should be cool to the touch. Inside of the projector can be very hot since these machines operator under high temperatures.</p>
<h2><strong>Replacing the </strong><strong><a href="http://www.discount-merchant.com/sanyo-poa-lmp107-replacement-projector-lamp-with-housing-by-philips.html#.WIgtBZI_Uwg" target="_blank">Sanyo POA-LMP107 (610 330 4564)</a></strong> lamp</h2>
<p><strong></strong><em>Caution: Don&#8217;t touch the screen or the actual bulb with your finger since the oil from your skin can cause a black spot on the bulb.</em></p>
<p><a href="http://www.fixyourdlp.com/uploads/PLC-XE32LampCover.jpg"><img fetchpriority="high" decoding="async" class="alignleft" style="margin-left: 15px;margin-right: 15px" src="http://www.fixyourdlp.com/uploads/PLC-XE32LampCover-300x183.jpg" alt="Sanyo PLC-XE32 Lamp Cover, Sanyo POA-LMP107 (service parts no 610 330 4564)" width="300" height="183" /></a>1. Underneath the <strong>Sanyo PLC-XW50/PLC-XW55 projector</strong> you&#8217;ll find the Lamp Hazard cover. Gently turn it upside down protecting the top of the projector. Using a Philips screwdriver loosen the screw holding the cover in place. Put the cover to one side.</p>
<p>2. Remove the two screws on either side of each the <strong></strong><strong><a href="http://www.discount-merchant.com/sanyo-poa-lmp107-replacement-projector-lamp-with-housing-by-philips.html#.WIgtBZI_Uwg" target="_blank">Sanyo POA-LMP107 (service parts no 610 330 4564)</a></strong> lamp. Grab the handle on the lamp cage and gently pull out the lamp. Place to one side. Be sure to dispose of the lamp properly through a local recycling program.</p>
<p>3. Take the new<strong><a href="http://www.discount-merchant.com/sanyo-poa-lmp53-replacement-projector-lamp-with-housing-by-philips.html#.VqG2zFIhvbE"><strong></strong><strong> </strong></a></strong><strong></strong><strong><a href="http://www.discount-merchant.com/sanyo-poa-lmp107-replacement-projector-lamp-with-housing-by-philips.html#.WIgtBZI_Uwg" target="_blank">Sanyo POA-LMP107 (610-330-4564)</a></strong> lamp cage by the handle and gently maneuver it into place.</p>
<p><a href="http://www.fixyourdlp.com/uploads/PLC-XE32LampInside.jpg"><img loading="lazy" decoding="async" class="alignright" style="margin-left: 20px;margin-right: 20px" src="http://www.fixyourdlp.com/uploads/PLC-XE32LampInside-300x207.jpg" alt="Sanyo PLC-XE32 Lamp Assembly, Sanyo POA-LMP107 (service parts no 610 330 4564)" width="218" height="150" /></a></p>
<p>4. Avoid touching the glass or the bulb. The lamp should slide in easily – don’t force it. Once the lamp is in, tighten the screws on the Lamp Assembly.</p>
<p>5. Replace the Lamp Hazard Cover and tighten screws.</p>
<p>6. Re-connect the power cord and turn on the <strong>Sanyo PLC-XW50/PLC-XW55</strong> projector.</p>
<h3><strong>Resetting the Lamp Replacement counter on the </strong>Sanyo PLC-XW50/PLC-XW55 <em></em></h3>
<p><em>Reset the Lamp Replacement Counter only when the <strong><a href="http://www.discount-merchant.com/sanyo-poa-lmp107-replacement-projector-lamp-with-housing-by-philips.html#.WIgtBZI_Uwg" target="_blank">Sanyo POA-LMP107 (service parts no 610 330 4564)</a></strong> lamps has been replaced.</em></p>
<p><em>Do not operate the projectors while any of the lamps are removed as this may result in malfunctions,  fire hazard and other accidents</em>.</p>
<p><a href="http://www.fixyourdlp.com/uploads/PLC-XE32Reset.jpg"><img loading="lazy" decoding="async" class="alignleft" style="margin-left: 20px;margin-right: 20px" src="http://www.fixyourdlp.com/uploads/PLC-XE32Reset-300x150.jpg" alt="Sanyo PLC-XW50/PLC-XW55 lamp reset option, Sanyo POA-LMP107 (service parts no 610 330 4564)" width="300" height="150" /></a></p>
<ul>
<li>Turn the <strong>Sanyo PLC-XW50/PLC-XW55</strong> projector on.</li>
<li>Press the <strong>Menu</strong> option to display the <strong>On-Screen Menu</strong>.</li>
<li>Press <strong>Point left/right button(s)</strong> to move a red frame poster to <strong>Setting Menu</strong> icon.</li>
<li>Press the black arrow point button to move the red framed pointer to the Setting Menu Icon.</li>
<li>Press <strong>Point Down</strong> button to move the red frame pointer to <strong>Lamp counter reset</strong>.</li>
<li>Press the <strong>Select</strong> button.</li>
</ul>
<ul>
<li>Another confirmation dialog box appears, select <strong>YES</strong>.<a href="http://www.fixyourdlp.com/uploads/PLC-XE32Reset2.jpg"><img loading="lazy" decoding="async" class="alignright" style="margin-left: 15px;margin-right: 15px" src="http://www.fixyourdlp.com/uploads/PLC-XE32Reset2.jpg" alt="Sanyo PLC-XW50/PLC-XW55, Sanyo POA-LMP107 (service parts no 610 330 4564)" width="231" height="198" /></a></li>
</ul>
<ul>
<li>The Lamp box will disappear and the <strong>Lamp Replace Dialog</strong> box appears.</li>
<li>Select <strong>YES</strong> to reset <strong>Lamp Replace Counter</strong>.</li>
</ul>
<p><strong>NOTE</strong>: When you reset the Lamp Replace Counter the <strong>Lamp Replace</strong> indicator stops lighting.</p>
<p>Clean your filter before before using the  <strong></strong><strong>Sanyo PLC-XW50/PLC-XW55</strong> projector to ensure a longer life for your newly installed projector lamp.</p>
<p>Cleaning the air your filter in the <strong></strong><strong></strong><strong>Sanyo PLC-XW50/PLC-XW55</strong> will ensure a longer life for your newly installed <strong><a href="http://www.discount-merchant.com/sanyo-poa-lmp107-replacement-projector-lamp-with-housing-by-philips.html#.WIgtBZI_Uwg" target="_blank">Sanyo POA-LMP107 (service parts no 610 330 4564)</a></strong> projector lamp.</p>
<p>&nbsp;</p>
<p>The post <a rel="nofollow" href="http://www.fixyourdlp.com/2012/01/18/installing-a-new-lamp-for-sanyo-plc-xw50plc-xw55-projectors/">Installing a new lamp for Sanyo PLC-XW50/PLC-XW55 projectors</a> appeared first on <a rel="nofollow" href="http://www.fixyourdlp.com">DLP Lamp Guide - LCD and DLP Repair Tips - Fix Your DLP - FixYourDLP.com</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>http://www.fixyourdlp.com/2012/01/18/installing-a-new-lamp-for-sanyo-plc-xw50plc-xw55-projectors/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/?utm_source=w3tc&utm_medium=footer_comment&utm_campaign=free_plugin

Page Caching using Disk: Enhanced 
Minified using Disk
Fragment Caching 0/0 fragments using Disk

Served from: www.fixyourdlp.com @ 2026-11-18 07:15:23 by W3 Total Cache
-->