<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Sanyo PLV-Z1C projector &#8211; DLP Lamp Guide &#8211; LCD and DLP Repair Tips &#8211; Fix Your DLP &#8211; FixYourDLP.com</title>
	<atom:link href="http://www.fixyourdlp.com/tag/sanyo-plv-z1c-projector/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.fixyourdlp.com</link>
	<description>Your Community For DLP Projector Repair Tips!</description>
	<lastBuildDate>Fri, 13 Jan 2017 07:05:41 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>
	<item>
		<title>Installing a Sanyo PLV-Z1C projector lamp</title>
		<link>http://www.fixyourdlp.com/2014/04/30/installing-sanyo-plv-z1c-projector-lamp/</link>
					<comments>http://www.fixyourdlp.com/2014/04/30/installing-sanyo-plv-z1c-projector-lamp/#respond</comments>
		
		<dc:creator><![CDATA[Shelagh McNally]]></dc:creator>
		<pubDate>Thu, 01 May 2014 05:37:00 +0000</pubDate>
				<category><![CDATA[FixYourDLP]]></category>
		<category><![CDATA[Projector Lamp Replacement Guides]]></category>
		<category><![CDATA[replace projector lamp for Sanyo projectors]]></category>
		<category><![CDATA[Sanyo PLV-Z1C projector]]></category>
		<category><![CDATA[Sanyo POA-LMP54]]></category>
		<guid isPermaLink="false">http://www.fixyourdlp.com/?p=19512</guid>

					<description><![CDATA[<p>Changing the Sanyo PLV-Z1C projector lamp is simple when you understand the technology. NOTE: This guide is also compatible with the Sanyo LP-Z1 (K) projector. Authentic projector lamps are the way to go Invest in an authentic Sanyo PLV-Z1C projector &#8230;</p>
<p class="read-more"> <a class="" href="http://www.fixyourdlp.com/2014/04/30/installing-sanyo-plv-z1c-projector-lamp/"> <span class="screen-reader-text">Installing a Sanyo PLV-Z1C projector lamp</span> Read More &#187;</a></p>
<p>The post <a rel="nofollow" href="http://www.fixyourdlp.com/2014/04/30/installing-sanyo-plv-z1c-projector-lamp/">Installing a Sanyo PLV-Z1C projector lamp</a> appeared first on <a rel="nofollow" href="http://www.fixyourdlp.com">DLP Lamp Guide - LCD and DLP Repair Tips - Fix Your DLP - FixYourDLP.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><a href="http://www.fixyourdlp.com/uploads/PLV-Z1.jpg"><img fetchpriority="high" decoding="async" class="alignright wp-image-2757 size-medium" src="http://www.fixyourdlp.com/uploads/PLV-Z1-300x205.jpg" alt="Sanyo PLV-Z1C Projector_lamp" width="300" height="205" srcset="http://www.fixyourdlp.com/uploads/PLV-Z1-300x205.jpg 300w, http://www.fixyourdlp.com/uploads/PLV-Z1.jpg 600w" sizes="(max-width: 300px) 100vw, 300px" /></a>Changing the Sanyo PLV-Z1C projector lamp is simple when you understand the technology.</h2>
<p><strong>NOTE: This guide is also compatible with the Sanyo LP-Z1 (K) projector.</strong></p>
<h4><strong>Authentic projector lamps are the way to go<br />
</strong></h4>
<p>Invest in an authentic Sanyo PLV-Z1C projector lamp. It&#8217;s the best insurance you can have to keep your Sanyo PLV-Z1C projector working. Avoid the temptation to buy a cheaper priced lamp online from popular sites. These bargain lamps are <a href="../2011/12/02/7-tips-for-spotting-counterfeits/" target="_blank">usually counterfeit lamps</a> created with inferior parts that can damage your projector.</p>
<p>They <a href="../2011/11/11/go-with-original-replacement-projection-lamps/" target="_blank">may end up costing you more</a> in the long run. Authentic projector lamps have been manufactured with reliable parts that work with the <a href="../2011/11/21/protect-yourself-against-counterfeits/" target="_blank">sensitive mechanisms</a> in your <strong>Sanyo PLV-Z1C projector</strong>. These authentic projector lamps come with a guarantee and won’t make your projector’s warranty invalid.</p>
<p>When it’s time to change your projector lamp on your <strong>Sanyo PLV-Z1C</strong> projector, you’ll notice the yellow light blinking on the <strong>Lamp Indicator</strong> found on the top control panel. Buy a <a href="http://www.discount-merchant.com/sanyo-poa-lmp54-replacement-projector-lamp-with-housing-by-philips.html#.WATCtFshvbE" target="_blank">Sanyo POA-LMP54 (service parts no 610 302 5933)</a> lamp replacement.</p>
<h4>Instructions for projector <strong>lamp replacement</strong></h4>
<p><a href="http://www.fixyourdlp.com/uploads/RemoveCover.jpg"><img decoding="async" class="alignleft wp-image-2759" style="margin: 15px;" src="http://www.fixyourdlp.com/uploads/RemoveCover-300x161.jpg" alt="Remove Lamp Cover on Sanyo PLV-Z1C Projector_lamp" width="300" height="161" srcset="http://www.fixyourdlp.com/uploads/RemoveCover-300x161.jpg 300w, http://www.fixyourdlp.com/uploads/RemoveCover.jpg 510w" sizes="(max-width: 300px) 100vw, 300px" /></a>1. Turn off the projector and unplug the AC cord.Allow the <strong>Sanyo PLV-Z1C</strong> projector to cool for at least 45 minutes. Don&#8217;t open the projector until it is cool to the touch. These projectors operate under high temperatures.</p>
<p>2. Place the <strong>Sanyo PLV-Z1C</strong> on something soft and turn it upside down. Loosen the screw holding the lamp cover in place (found over top of the ventilation holes).</p>
<p><a href="http://www.fixyourdlp.com/uploads/ReplaceLamp.jpg"><img decoding="async" class="alignleft wp-image-2760" style="margin: 10px 15px;" src="http://www.fixyourdlp.com/uploads/ReplaceLamp-300x164.jpg" alt="Replace POA-LMP54 in Sanyo PLV-Z1C Projector_lamp" width="300" height="164" srcset="http://www.fixyourdlp.com/uploads/ReplaceLamp-300x164.jpg 300w, http://www.fixyourdlp.com/uploads/ReplaceLamp.jpg 525w" sizes="(max-width: 300px) 100vw, 300px" /></a>3. Loosen the two screws keeping the <a href="http://www.discount-merchant.com/sanyo-poa-lmp54-replacement-projector-lamp-with-housing-by-philips.html#.WATCtFshvbE" target="_blank">Sanyo POA-LMP54 (610 302 5933)</a> lamp in place. Grab the handle on the projector lamp cage and gently remove the lamp. Place to one side. <strong>Your old projector lamp should be properly recycled. These lamps contain mercury and can’t be placed into regular garbage.</strong></p>
<p>4. Take the new <a href="http://www.discount-merchant.com/sanyo-poa-lmp54-replacement-projector-lamp-with-housing-by-philips.html#.WATCtFshvbE" target="_blank">Sanyo POA-LMP54 (6103025933)</a> projector lamp cage by the handle and gently maneuver it into place. Avoid touching the glass or the bulb since the oil from your fingers may cause black spots on the bulb when the projector heats up. The lamp should slide in easily – don’t force it.</p>
<p>5. Tighten the two screws on the Lamp Assembly for the <a href="http://www.discount-merchant.com/sanyo-poa-lmp54-replacement-projector-lamp-with-housing-by-philips.html#.WATCtFshvbE" target="_blank">Sanyo POA-LMP54 (610 302 5933)</a>.</p>
<p>6. Replace and tighten the three screws on either side of Lamp Hazard Cover. Let the projector stand for five minutes so the projector lamp can stabilize. Re-connect the power cord and turn on the <strong>Sanyo PLV-Z1C </strong> projector. You&#8217;ll need to reset the Lamp Counter.</p>
<h4><strong>RESETTING THE Sanyo PLV-Z1C LAMP CONTROL MODE</strong></h4>
<p>Reset the Lamp Control Mode only when <strong><a href="http://www.discount-merchant.com/sanyo-poa-lmp54-replacement-projector-lamp-with-housing-by-philips.html#.WATCtFshvbE" target="_blank">Sanyo POA-LMP54 (service parts no 610 302 5933)</a> </strong>projector lamp has been replaced. Do not operate the projectors while any of the lamps are removed as this may result in malfunctions, fire hazard and other accidents.</p>
<p><a href="http://www.fixyourdlp.com/uploads/ResetLampScreen.jpg"><img loading="lazy" decoding="async" class="alignleft wp-image-2762 size-medium" style="margin: 10px 20px;" src="http://www.fixyourdlp.com/uploads/ResetLampScreen-300x240.jpg" alt="Reset Lamp Screen for Sanyo PLV-Z1 Projector_lamp" width="300" height="240" srcset="http://www.fixyourdlp.com/uploads/ResetLampScreen-300x240.jpg 300w, http://www.fixyourdlp.com/uploads/ResetLampScreen.jpg 413w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a></p>
<ul>
<li>Turn the <strong>Sanyo PLV-Z1C</strong> projector on. Press the <strong>Menu</strong> option to display the <strong>On-Screen Menu</strong>. Scroll down to the <strong>Setting</strong> option.</li>
<li>Select <strong>Lamp Control</strong>.</li>
<li>A second screen will appear.</li>
<li><a href="http://www.fixyourdlp.com/uploads/ResetLampScreen-2.jpg"><img loading="lazy" decoding="async" class="alignnone" src="http://www.fixyourdlp.com/uploads/ResetLampScreen-2-300x106.jpg" alt="Second Lamp Reset Screen for Sanyo PLV-Z1C Projector_lamp" width="300" height="106" /></a></li>
<li>Press <strong>Point left/right button(s)</strong> to move to move the red frame pointer to <strong>Lamp counter reset</strong>.</li>
<li>Press the <strong>Select</strong> button.</li>
<li>Another confirmation dialog box appears, select <strong>YES</strong>.</li>
<li>The Lamp box will disappear and the <strong>Lamp Replace Dialog</strong> box appears.</li>
<li>Select <strong>YES</strong> to reset <strong>Lamp Replace Counter</strong>.</li>
</ul>
<h4><strong>Make your new <em><strong><em><strong><em><strong><a href="http://www.discount-merchant.com/sanyo-poa-lmp54-replacement-projector-lamp-with-housing-by-philips.html#.WATCtFshvbE" target="_blank">Sanyo POA-LMP54</a></strong></em></strong></em></strong></em></strong> projector lamp last longer</h4>
<p>To maintain the life of your newly installed <a href="http://www.discount-merchant.com/sanyo-poa-lmp54-replacement-projector-lamp-with-housing-by-philips.html#.WATCtFshvbE" target="_blank">Sanyo POA-LMP54 (610 302 5933)</a>, wait at least five minutes before turning the <strong>Sanyo PLV-Z1C</strong> projector off. Don’t operate the projector continuously without letting it stand for at least one hour turned off every 24 hours. Regular cleaning of the air filter will also prolong lamp life.<strong><br />
</strong></p>
<h5><a href="http://www.fixyourdlp.com/uploads/Sanyo_lamp_bulb_replacement.jpg"><img loading="lazy" decoding="async" class="alignleft" style="margin-left: 20px; margin-right: 20px;" src="http://www.fixyourdlp.com/uploads/Sanyo_lamp_bulb_replacement-300x228.jpg" alt="Sanyo_lamp_bulb_replacement_Sanyo_ PLV-Z1C _projector_lamp" width="240" height="183" /></a></h5>
<h4>Looking for a less expensive option? Want more information? Watch our <a href="http://www.youtube.com/watch?v=cBpiCUGms9s&amp;feature=youtu.be" target="_blank">step-by-step video</a> on replacing only the <a href="http://www.discount-merchant.com/sanyo-poa-lmp54-replacement-projector-lamp-with-housing-by-philips.html#.WATCtFshvbE" target="_blank">Sanyo POA-LMP54 (service parts no 610 302 5933)</a> bulb instead of the entire lamp housing.</h4>
<h4></h4>
<h4></h4>
<h4></h4>
<p>&nbsp;</p>
<p>The post <a rel="nofollow" href="http://www.fixyourdlp.com/2014/04/30/installing-sanyo-plv-z1c-projector-lamp/">Installing a Sanyo PLV-Z1C projector lamp</a> appeared first on <a rel="nofollow" href="http://www.fixyourdlp.com">DLP Lamp Guide - LCD and DLP Repair Tips - Fix Your DLP - FixYourDLP.com</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>http://www.fixyourdlp.com/2014/04/30/installing-sanyo-plv-z1c-projector-lamp/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/?utm_source=w3tc&utm_medium=footer_comment&utm_campaign=free_plugin

Page Caching using Disk: Enhanced 
Minified using Disk
Fragment Caching 0/0 fragments using Disk

Served from: www.fixyourdlp.com @ 2026-11-10 18:24:46 by W3 Total Cache
-->